Top of page |
Réf. 02010001
|
Shielded glove box 4R CORIAN® Evolution
Principle
The shielded glove boxes 4R from Lemer Pax allow safe handling of isotopes during
elution, fractionating, taging and measuring. It is designed to protect the operators from
both contamination and isotope radiation. |
 |
 |
 |
Top of page |
Ref. 02010034
|
FDG Shielded glove box
CORIAN® Evolution
Principle
The ventilated shielded glove boxes 2 glove ports from Lemer Pax allows safe
handling of high energy isotopes (up to 511 Kev) during fractionating, taging and
measuring operations. It is designed to protect the operators from both contamination and
high energy radiation. |
 |
 |
 |
Top of page |
Ref. 0215002
|
Shielded bench
Principle
Designed for handling radioactive material that does not need the added protection
of a vented, shielded glove box, the shielded bench provides an easy decontaminable,
shielded work area. The steel constructed bench includes a movable front shield lead glass
window for viewing the working area.
A shielded, 3 shelves, key locked storage safe is integrated under the lower left side of
the working area. |
 |
 |
 |
Top of page |
Shielded hot cells
|
FDG - production shielded hot cells
Principle
See the PDF file for more informations on the 2 products :
- FDG - Shielded hot
cell with slave manipulators
- FDG synthesis module shielded hot cells |
 |
 |
 |
Top of page |
Ref. HFLS
|
Shielded laminar flow hood.
Laminar flow hood.
Principle
The laminar flow hood provides safety for the operator and environment during the
delicate procedures of taging, dissection, evaporation etc.
The shielded version also provides protection from radiation emmiting isotopes. |
 |
 |
 |
Top of page |
Ref. 02000030 (width 1800)
02000031 (width 1200)
|
Shielded Hood
Principle
The ventilated shielded hood with integrated sink and energy supplies allows safe
handling of volatile radioactive nuclides.
Its design permits to protect the operator from irradiation and preserve the environment
from any dangerous contamination. This protection is accomplished through the exclusive
use of acrylic resin front panel which stops the beta rays from 32P, 14C, 32S, 89 Sv, 90
Sv, 90 y. The two lateral and back panels are 1 mm lead shielded. |
 |
 |
 |
Top of page |
Type PSW - Type PSWG
|
FDG Syringe shield
Principle
These tungsten syringe shield with a sliding shielded cover improve the protection
for the operators from the exposition of high energy radiation such as the one emitted by
the iodine 131 (360 Kev), the fluoride 18, oxygen 15, carbon 11 (511 Kev) and this in
particular on the syringes piston side. |
 |
 |
 |
Top of page |
Ref. CTTW
|
Tungsten FDG transport containers
Principle
The tungsten FDG transport containers allow safe handling of the FDG vials during
the different operations of transport and storage in order to protect both the operator
and the environment from the contamination and exposition of the isotope radiation. These
containers are perfectly protected from leaks by design. |
 |
 |
 |
Top of page |
CT1035 - CT1535 ...
|
Shielded containers
principle
The shielded containers from Lemer Pax allow safe handling of the vials during the
different operations of transfer and storage in order to protect both the operator and the
environment from the contamination and exposition of the isotope radiation. These
containers are perfectly protected from leaks by design. |
 |
 |
 |
Top of page |
Ref. CHT
|
FDG transport trolley
Principle
The transport trolleys of Lemer Pax with an additive lead protection are designed
to reduce the contact of the doses for the users and their environments when they have to
carry radioactive products doses to their use place. The additive protection in lead
(thickness 30 mm), accessible by a shielded drawer, allows to transport either FDG mother
solutions already protected by their lead or tungsten container or some syringes with
their tungsten syringe shields that correspond to the injectable doses. |
 |
 |
 |
Top of page |
Ref. DIA
|
Manual remote-controlled FDG injection shielded system
Principle
The manual remote-controlled FDG injection shielded system from Lemer Pax allows to
protect the operators during the isotope injection, when connected to the patient by a
catheter, by using the manually activated remote system behind a protective screen. |
 |
 |
 |
Top of page |
Ref. : BPP30
|
Positron rolling radiation shield
Principle
The Lemer Pax positron shield protects the operator from high energy (511 Kev)
emitting isotopes and provides optimum accessibility towards the patient thanks to the 400
mm width at the arm level. This 30 mm pb shield is movable on heavy duty castors. |
 |
 |
 |
Top of page |
Ref. 02021100
|
PET synthesis module mini hot cell
Principle
The PET synthesis module mini hot cell preserves the operator from the positron
(511 Kev) emitting isotopes, the environment from radioactivity emissions and the products
during the different synthesis phases. An integrated ventilation/filtration system allows
to control air quality, exhaust of the calories and capture of radioactive particles. The
smooth inner cell surface is equipped with a stainless steel sliding tray for easy
maintenance operation. |
 |
 |
 |
Top of page |
Réf. 02020001
|
Acad 2000 dose calibrator
Principle
The ACAD 2000 calibrator provides a simple and accurate way of measuring the
activity both in curies (Ci) and becquerels (Bq) of radioisotopes emitting gamma rays.
Its main use is the calibration of the radiopharmaceutical doses injected to patients in
nuclear medicine imaging. |
 |
 |
 |
Top of page |
Ref. 02150021
|
Nuclear medicine bench with
decontaminable work area
Principle
This bench provides an easy to clean work area that can be equiped with all the
needed accessories to prepare and measure the injectable doses that do not have to be
prepared in a shielded glove box. |
 |
 |
 |
Top of page |
Ref. 02060000
|
Bench top beta shield
Principle
This 10 mm acrylic shield gives maximum beta radiation protection with an
effeciency level over 99,9% when using isotopes such as P32 or Strontium 89. |
 |
 |
 |
Top of page |
Type HBI
|
Table top shield
Principle
The clear table top shield protects the head and chest from radiation during
manipulation of radioactive materials. |
 |
 |
 |
Top of page |
Lead bricks
|
Lead bricks
Principle
The V shaped, or parallelepipedic lead bricks are designed for easy and versatile
use. Constructing a modular and movable chamber for containing gamma emitting sources for
manipulation or long term storage is quickly accomplished using interlocking bricks. In
option, those bricks are covered with a decontaminable finish. |

|
 |
 |
Top of page |
Ref. 800C - 800E - 800N
|
Radiation protective glasses
Principle
There are three models of Lemer-Claireux protective glasses available :
- Model 800C with integrated lead glass side shields.
- Model 800E, a modern wrap-around design with tungsten side shields, giving lighter
weight and more comfortable wearing.
- Model 800N, standard lead glasses without side shields. |
 |
 |
 |
Top of page |
Ref.
PM0 - PM1 - PM2
- PM4 - PM5
|
Protective floor screens
Principle
The Lemer Pax mobile screens providing 2,00 mm lead protection are realised in
flame resistant materials with contemporary design.
The 2,00 mm lead equivalent lead glass window assure an homogenous protection with the
lead lined opaque panel finished with a white pearl durable surface. The entire screens
are mounted on heavy duty steel legs and pivoting ball bearings casters with brakes. |
 |
 |
 |
Top of page |
Lead aprons STOP-X
|
Lead aprons STOP-X
Principle
For nuclear medicine technologist.
See the PDF file for more details. |

|
 |
 |
Top of page |
Ref. 02030001
|
Shielded agitator
Principle
Designed to agitate radioisotope marked human serum albumin microspheres. As this
solution must be agitated for long periods of time, it is not advisable to hold the active
vial in the hands during this procedure. |
 |
 |
 |
Top of page |
Ref. 02030000
|
Thermostatically controlled
shielded heating system
Principle
The Lemer Pax controlled shielded heating system is specially designed to prepare
the radiopharmaceutical penicillin type vials used in «cardiolite, Mag
3, and other tagged colloïdal type kits and all radiopharmaceuticals that need to
be heated up to 160° C. |
 |
 |
 |
Top of page |
Ref. 02020000
Ref. 02020050
|
Under bench lead lined refrigerator
Principle
The under bench lead lined refrigerator allows the storage of radio pharmaceuticals
and tagged biological materials. It is designed to be easily placed under the bench and to
optimize the laboratory surface. |
 |
 |
 |
Top of page |
Ref. SC3
|
Shielded syringe carrier
Principle
These specially designed shielded containers provide optimum safety for the
transport and storage of loaded vials, syringes, etc
|
 |
 |
 |
Top of page |
Ref. VS5
|
Shielded vial case
Principle
These specially designed shielded containers provide optimum safety for the
transport and storage of loaded vials, syringes, etc
|
 |
 |
 |
Top of page |
Ref. SS25
|
Shielded safe
Principle
These specially designed shielded containers provide optimum safety for the
transport and storage of loaded vials, syringes, etc
|
 |
 |
 |
Top of page |
Type CT
|
Shielded containers
Principle
The shielded containers from Lemer Pax allow safe handling of the vials during the
different operations of transfer and storage in order to protect both the operator and the
environment from the contamination and exposition of the isotope radiation. These
containers are perfectly protected from leaks by design. |
 |
 |
 |
Top of page |
Ref. PFE - PME - PHE
|
Lead glass vial shields
Principle
The unique design of the Lemer Vial Shields offers maximum visibility and easy of
use while giving optimum isotope storage with minimum exposure to the operator. The
specially designed double top system permits insertion of the needle through a shielded
inner top whithout undo exposure to the operator.
Various models are available to accomodate mother solutions from different types of TC 99
generators. |
 |
 |
 |
- Next Page -
|


Use this link on the chosen product to contact us for more
informations or for a commercial contact.

Use this link to download a PDF file (average
wheight100 Kos).This file contain more complete informations about the product. |