Go to Top of Page Top of page

Réf. 02010001

Shielded glove box 4R CORIAN® Evolution

Principle
The shielded glove boxes 4R from Lemer Pax allow safe handling of isotopes during elution, fractionating, taging and measuring. It is designed to protect the operators from both contamination and isotope radiation.

 

Go to Top of Page Top of page

Ref. 02010034

FDG Shielded glove box
CORIAN® Evolution

Principle
The ventilated shielded glove boxes 2 glove ports from Lemer Pax allows safe handling of high energy isotopes (up to 511 Kev) during fractionating, taging and measuring operations. It is designed to protect the operators from both contamination and high energy radiation.

 

Go to Top of Page Top of page

Ref. 0215002

Shielded bench

Principle
Designed for handling radioactive material that does not need the added protection of a vented, shielded glove box, the shielded bench provides an easy decontaminable, shielded work area. The steel constructed bench includes a movable front shield lead glass window for viewing the working area.
A shielded, 3 shelves, key locked storage safe is integrated under the lower left side of the working area.

   

Go to Top of Page Top of page

Shielded hot cells

FDG - production shielded hot cells

Principle
See the PDF file for more informations on the 2 products :

- FDG - Shielded hot cell with slave manipulators
- FDG synthesis module shielded hot cells

 

Go to Top of Page Top of page

Ref. HFLS

Shielded laminar flow hood.
Laminar flow hood.

Principle
The laminar flow hood provides safety for the operator and environment during the delicate procedures of taging, dissection, evaporation etc.
The shielded version also provides protection from radiation emmiting isotopes.

   

Go to Top of Page Top of page

Ref. 02000030 (width 1800)
02000031 (width 1200)

Shielded Hood

Principle
The ventilated shielded hood with integrated sink and energy supplies allows safe handling of volatile radioactive nuclides.
Its design permits to protect the operator from irradiation and preserve the environment from any dangerous contamination. This protection is accomplished through the exclusive use of acrylic resin front panel which stops the beta rays from 32P, 14C, 32S, 89 Sv, 90 Sv, 90 y. The two lateral and back panels are 1 mm lead shielded.

     

Go to Top of Page Top of page

Type PSW - Type PSWG

FDG Syringe shield

Principle
These tungsten syringe shield with a sliding shielded cover improve the protection for the operators from the exposition of high energy radiation such as the one emitted by the iodine 131 (360 Kev), the fluoride 18, oxygen 15, carbon 11 (511 Kev) and this in particular on the syringe’s piston side.

 

Go to Top of Page Top of page

Ref. CTTW

Tungsten FDG transport containers

Principle
The tungsten FDG transport containers allow safe handling of the FDG vials during the different operations of transport and storage in order to protect both the operator and the environment from the contamination and exposition of the isotope radiation. These containers are perfectly protected from leaks by design.

 

Go to Top of Page Top of page

CT1035 - CT1535 ...

Shielded containers

principle
The shielded containers from Lemer Pax allow safe handling of the vials during the different operations of transfer and storage in order to protect both the operator and the environment from the contamination and exposition of the isotope radiation. These containers are perfectly protected from leaks by design.

 

Go to Top of Page Top of page

Ref. CHT

FDG transport trolley

Principle
The transport trolleys of Lemer Pax with an additive lead protection are designed to reduce the contact of the doses for the users and their environments when they have to carry radioactive products doses to their use place. The additive protection in lead (thickness 30 mm), accessible by a shielded drawer, allows to transport either FDG mother solutions already protected by their lead or tungsten container or some syringes with their tungsten syringe shields that correspond to the injectable doses.

  

Go to Top of Page Top of page

Ref. DIA

Manual remote-controlled FDG injection shielded system

Principle
The manual remote-controlled FDG injection shielded system from Lemer Pax allows to protect the operators during the isotope injection, when connected to the patient by a catheter, by using the manually activated remote system behind a protective screen.

 

Go to Top of Page Top of page

Ref. : BPP30

Positron rolling radiation shield

Principle
The Lemer Pax positron shield protects the operator from high energy (511 Kev) emitting isotopes and provides optimum accessibility towards the patient thanks to the 400 mm width at the arm level. This 30 mm pb shield is movable on heavy duty castors.

  

Go to Top of Page Top of page

Ref. 02021100

PET synthesis module mini hot cell

Principle
The PET synthesis module mini hot cell preserves the operator from the positron (511 Kev) emitting isotopes, the environment from radioactivity emissions and the products during the different synthesis phases. An integrated ventilation/filtration system allows to control air quality, exhaust of the calories and capture of radioactive particles. The smooth inner cell surface is equipped with a stainless steel sliding tray for easy maintenance operation.

 

Go to Top of Page Top of page

Réf. 02020001

Acad 2000 dose calibrator

Principle
The ACAD 2000 calibrator provides a simple and accurate way of measuring the activity both in curies (Ci) and becquerels (Bq) of radioisotopes emitting gamma rays.
Its main use is the calibration of the radiopharmaceutical doses injected to patients in nuclear medicine imaging.

   

Go to Top of Page Top of page

Ref. 02150021

Nuclear medicine bench with
decontaminable work area

Principle
This bench provides an easy to clean work area that can be equiped with all the needed accessories to prepare and measure the injectable doses that do not have to be prepared in a shielded glove box.

  

Go to Top of Page Top of page

Ref. 02060000

Bench top beta shield

Principle
This 10 mm acrylic shield gives maximum beta radiation protection with an effeciency level over 99,9% when using isotopes such as P32 or Strontium 89.

 

Go to Top of Page Top of page

Type HBI

Table top shield

Principle
The clear table top shield protects the head and chest from radiation during manipulation of radioactive materials.

  

Go to Top of Page Top of page

Lead bricks  

Lead bricks

Principle
The V shaped, or parallelepipedic lead bricks are designed for easy and versatile use. Constructing a modular and movable chamber for containing gamma emitting sources for manipulation or long term storage is quickly accomplished using interlocking bricks. In option, those bricks are covered with a decontaminable finish.

   

Go to Top of Page Top of page

Ref. 800C - 800E - 800N

Radiation protective glasses

Principle
There are three models of Lemer-Claireux protective glasses available :
- Model 800C with integrated lead glass side shields.
- Model 800E, a modern wrap-around design with tungsten side shields, giving lighter weight and more comfortable wearing.
- Model 800N, standard lead glasses without side shields.

   

Go to Top of Page Top of page

Ref. PM0 - PM1 - PM2 
- PM4 - PM5  

Protective floor screens

Principle
The Lemer Pax mobile screens providing 2,00 mm lead protection are realised in flame resistant materials with contemporary design.
The 2,00 mm lead equivalent lead glass window assure an homogenous protection with the lead lined opaque panel finished with a white pearl durable surface. The entire screens are mounted on heavy duty steel legs and pivoting ball bearings casters with brakes.

 

Go to Top of Page Top of page

Lead aprons STOP-X

Lead aprons STOP-X

Principle
For nuclear medicine technologist.
See the PDF file for more details.

 

Go to Top of Page Top of page

Ref. 02030001

Shielded agitator

Principle
Designed to agitate radioisotope marked human serum albumin microspheres. As this solution must be agitated for long periods of time, it is not advisable to hold the active vial in the hands during this procedure.

  

Go to Top of Page Top of page

Ref. 02030000

Thermostatically controlled
shielded heating system

Principle
The Lemer Pax controlled shielded heating system is specially designed to prepare the radiopharmaceutical penicillin type vials used in «cardiolite”, “Mag 3”, and other tagged colloïdal type kits and all radiopharmaceuticals that need to be heated up to 160° C.

   

Go to Top of Page Top of page

Ref. 02020000
Ref. 02020050

Under bench lead lined refrigerator

Principle
The under bench lead lined refrigerator allows the storage of radio pharmaceuticals and tagged biological materials. It is designed to be easily placed under the bench and to optimize the laboratory surface.

 

Go to Top of Page Top of page

Ref. SC3

Shielded syringe carrier

Principle
These specially designed shielded containers provide optimum safety for the transport and storage of loaded vials, syringes, etc…

 

Go to Top of Page Top of page

Ref. VS5

Shielded vial case

Principle
These specially designed shielded containers provide optimum safety for the transport and storage of loaded vials, syringes, etc…

   

Go to Top of Page Top of page

Ref. SS25

Shielded safe

Principle
These specially designed shielded containers provide optimum safety for the transport and storage of loaded vials, syringes, etc…

   

Go to Top of Page Top of page

Type CT

Shielded containers

Principle
The shielded containers from Lemer Pax allow safe handling of the vials during the different operations of transfer and storage in order to protect both the operator and the environment from the contamination and exposition of the isotope radiation. These containers are perfectly protected from leaks by design.

    

Go to Top of Page Top of page

Ref. PFE - PME - PHE

Lead glass vial shields

Principle
The unique design of the Lemer Vial Shields offers maximum visibility and easy of use while giving optimum isotope storage with minimum exposure to the operator. The specially designed double top system permits insertion of the needle through a shielded inner top whithout undo exposure to the operator.
Various models are available to accomodate mother solutions from different types of TC 99 generators.


- Next Page -

 


  

Use this link on the chosen product to contact us for more informations or for a commercial contact.

Use this link to download a PDF file (average wheight100 Kos).This file contain more complete informations about the product.

Home  |  About  |  Our Products  |  Contact